

10 PIPING REFRIGERANT AND OIL PIPING COMPONENTS. 16 CONTROL AND POWER PANELS CONTROL PANEL AND POWER PANEL. 20 TRANSDUCERS, PRESSURE CUTOUTS AND TEMP SENSORS. 48 WIRE HARNESS CONNECTORS - FIELD REPLACEMENT PART NUMBERS. 50 CHILLER OPTIONS YCAL CHIILER OPTIONS - KITS. 56 REMOTE CURRENT/TEMPERATURE RESET PARTS BREAKDOWN. WARNINGHIGH VOLTAGE Is used in the operation of this equipment. DEATH OR SERIOUS INJURY may result if personnel fail to observe safety precautions.Work on electronic equipment should not be undertaken unless the individual(s) have been trained in the proper maintenance of equipment and is (are) familiar with its potential hazards. Shut off power supply to the equipment before beginning work and follow lockout procedures. When working inside equipment with power off, take care to discharge every capacitor likely to hold dangerous potential. Be careful not to contact high voltage connections when installing or operating this equipment.
#York ycal low ambient kit series#
YCAL0060SC28XAA1 2 3 4BASE PRODUCT TYPE Y C Aĥ 6 7 8NOMINAL CAPACITY # Tons/Kw 0014 to 0080ĩUNIT DESIGNATOR S R Standard Unit Heat Pumpġ1 12 13VOLTAGE/STARTER 1 2 4 4 5 7 8 0 6 8ġ4 15DESIGN/DEVELOPMENT LEVEL :Design Series A :Engineering Change or PIN Level UNIT NOMENCLATURE NAMEPLATE ENGINEERING DATABasic Part Number Voltages as low as 50 volts may cause death.2YORK INTERNATIONAL LOW VOLTAGEDO NOT be misled by the term low voltage. : YORK # : Chiller : Air Cooled L : Scroll YORK YCAL HIGH AMBIENT KIT SERIES PART NUMBER letter codes16 17 18 19POWER FIELD X X S X S D B X: : : :Ģ0 21 22 23 24 25 26 27 28CONTROLS FIELDMP Supply TB L SP Supply TB H SP NF Disconnect Switch A SP Circuit Breaker w/ Lockable Handle : : : : : : : : Low Ambient Kit (factory) High Ambient Kit (factory) Both Low / High Ambient (factory) BAS/EMS Temp. Reset / Offset Spanish LCD & Keypad Display French LCD & Keypad Display German LCD & Keypad Display Discharge Pressure Transducers/ Readout Kit Suction Pressure Transducers / Readout Kit Both Discharge & Suction Pressure Transducers / Readout N.
#York ycal low ambient kit code#
American Safety Code (cU.L./cETL) No Listing (typically 50 HZ non-CE, non-U.L. YORK YCAL HIGH AMBIENT KIT CODEīrine (LBrT) :Thermal Storage :Chicago Relief Code Remote Control Panel Sequence Control & Automatic Lead TransferĢ9 30 31 32 33 34 35 36 37COMPRESSOR / PIPING FIELD # T # S C:Low Temp. MP = Multiple Point SP = Single Point NF = Non-Fused TB = Terminal Block Ser. Handles = Individual System Breaker & Lockable External Handleģ8 39 40 41 42 43 44EVAP.

FIELD 3 D W S A R: 300 PSIG DWP Waterside : Double Thick Insulation : Weld Flange Kit : Flow Switch : ASME Pressure Vessel & Associated Codes : Remote DX CoolerĤ5 46 47CONDENSER FIELD X C B P: : : : X: Aluminum Copper Black Fin Phenolic TEAO Fan MotorsĤ8 49 50 51 52 53 54CABINET FIELD X 1 2 3 4 5 6 7 8 B L: : : : : : : : : : Wire Condenser Headers Only (factory) Wire (Full Unit) Enc. Panels (factory) Louvered (Full Unit) Enc.

Panels (field) Acoustic Sound Blanketġ : 1" Deflection S : Seismic N : Neoprene Padsġst Year Parts Only 1st Year Parts & Labor 2nd Year Parts Only 2nd Year Parts & Labor 5 Year Compressor Parts Only 5 Year Compressor Parts & Labor Only 5 Year Units Parts Only 5 Year Unit Parts & Labor X :w/in OPTIONS FIELD, DENOTES NO OPTION SELECTED 4. Service Note: Pin Location 38 in Model Number will be X for 150# cooler. 1 EVAPORATOR COMPONENTS - MODELS YCAL0014 AND YCAL0020 SHOWN (REF. TABLE 1 EVAPORATOR COMPONENTS - 150 PSIG (SEE FIG. PER UNIT 1 1 1 1 1 4 1 2 1 2 2 1 1 DESCRIPTION Cooler, less Heater & Insulation (Items 2 thru 6) Head, Conn.
